High Voltage Circuit Breaker Test Instrument Touch Screen Hv Circuit Breaker Vibration Analyzer
Product Introduction
Our company provides customers with unique charm, excellent performance and stable quality transformer capacity characteristic tester, vlf cable tester, SF6 Gas Analyzer with strict quality management mode. Our company uses reactive methods, such as a toll free hotline service to listen to customer feedback. We strive to build a new highland of talent advantage in the era of knowledge economy and build the competitiveness of our company. We insist on the benign development direction of taking the market by brand and striving for quality by market.
HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer
high-voltage circuit breaker analyzer is suitable for mechanical characteristic testing of SF6 switches, GIS composite electrical appliances, vacuum switches, and oil switches.

High Voltage Circuit Breaker Analyzer Precautions
1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
2. The connect action of the test lines should be done before supply power to the instrument.
3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.
4. Try to use the special test leads and accessories provided by this instrument.
5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.
6. Avoid using it in humid, flammable and explosive environments.
7. The power supply of the instrument is 220V AC, and 380V is prohibited.





High Voltage Circuit Breaker Analyzer Technical Characteristics
Test channels | 12 channels with 25V, the current is 50mA |
Transducer | One analog transducer. |
TIME | |
Recording time length | 0~20.0s |
Time accuracy | ±0.l%reading ± 2 LSB |
Resolution | 0.1ms |
Motion | |
Range | 0~1000mm |
Accuracy | ±1% reading ±1LSB |
Resolution | 0.1mm |
Velocity | |
Ranges | 0.01~20.00m/s |
Accuracy | ±1%reading ±1LSB |
Resolution | 0.01m/s |
DC POWER | |
Ranges | 5~260V |
Max current | 20A |
Accuracy | ±1%reading ±1LSB |
Load change | ≤1% |
TRIGGER | |
Voltage | 5~260V |
Current | 0.1-20A |
Transducer | The transducer states changes |
Channels | Channels states changed |
DIMENSIONS | 415mm×320mm×168mm |
WEIGHT | 8kg |
OPERATION TEMPERATURE | -10℃~50℃ |
HUMIDITY | ≤80% RH |
POWER SUPPLY | |
Voltage | AC 220V±10% |
FREQUENCE | 50Hz±10% |
SAFETY | |
Insulation resistance | >2MΩ |
Leakage current | <3.5mA |
Immunity | AC 1500V 50Hz, 1min. |



We mainly deals in High Voltage Circuit Breaker Test Instrument Touch Screen Hv Circuit Breaker Vibration Analyzer, and special specifications products can also be customized according to customer requirements. On the basis of independent development, we have learned and absorbed the latest research results in the field of science and technology in the world. For us, long-term loyal customers are more profitable than short-term customers.
Hot Tags: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system, CB dynamic mechanical analyzer, transformer dielectric loss tester, circuit breaker timing test machine, surge counter test kit, double storage oil filter, power analyzer three phase for electric motor, Single Phase Relay Test Kit