Good Vibration Resistance Thermal Gas Mass Flowmeter on Gas Leakage Measurement
Product Introduction
Strong technical strength, the use of scientific production management methods, and the selection of high-quality materials are the guarantee of our high-quality bdv testing machine, Transformer Routine Test, tan delta test kit price. Good quality, look at the details, so you can use it more at ease. We are willing to work together with you to move towards the future!
HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer
high-voltage circuit breaker analyzer is suitable for mechanical characteristic testing of SF6 switches, GIS composite electrical appliances, vacuum switches, and oil switches.

High Voltage Circuit Breaker Analyzer Precautions
1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
2. The connect action of the test lines should be done before supply power to the instrument.
3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.
4. Try to use the special test leads and accessories provided by this instrument.
5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.
6. Avoid using it in humid, flammable and explosive environments.
7. The power supply of the instrument is 220V AC, and 380V is prohibited.





High Voltage Circuit Breaker Analyzer Technical Characteristics
Test channels | 12 channels with 25V, the current is 50mA |
Transducer | One analog transducer. |
TIME | |
Recording time length | 0~20.0s |
Time accuracy | ±0.l%reading ± 2 LSB |
Resolution | 0.1ms |
Motion | |
Range | 0~1000mm |
Accuracy | ±1% reading ±1LSB |
Resolution | 0.1mm |
Velocity | |
Ranges | 0.01~20.00m/s |
Accuracy | ±1%reading ±1LSB |
Resolution | 0.01m/s |
DC POWER | |
Ranges | 5~260V |
Max current | 20A |
Accuracy | ±1%reading ±1LSB |
Load change | ≤1% |
TRIGGER | |
Voltage | 5~260V |
Current | 0.1-20A |
Transducer | The transducer states changes |
Channels | Channels states changed |
DIMENSIONS | 415mm×320mm×168mm |
WEIGHT | 8kg |
OPERATION TEMPERATURE | -10℃~50℃ |
HUMIDITY | ≤80% RH |
POWER SUPPLY | |
Voltage | AC 220V±10% |
FREQUENCE | 50Hz±10% |
SAFETY | |
Insulation resistance | >2MΩ |
Leakage current | <3.5mA |
Immunity | AC 1500V 50Hz, 1min. |



We will continue to put effort into R&D to ensure that our Good Vibration Resistance Thermal Gas Mass Flowmeter on Gas Leakage Measurement technology is at the forefront of the industry. Our pursuit is to put customers' needs in front of us at all times and strive to provide better technology, better products and better services. Our company has the competitive advantages of R&D, production, technical guidance, sales and service.
Hot Tags: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system, CB dynamic mechanical analyzer, vlf insulation meter, clamp on earth ground resistance tester, hv test transformer, sf6 dew point tester, Circuit Breaker Timing Test Equipment, high voltage phasing sticks
[[ProKeywords]]SPEC DATA
Send Inquiry