+86-312-6775656
GDKC-5000 Portable Transformer On Load Tap Changer Tester

GDKC-5000 Portable Transformer On Load Tap Changer Tester

The instrument for parameters of on load tap changer for transformers is a special instrument for measuring and analyzing the operating characteristics of on-load tap changer for transformers.
Send Inquiry
Product Details of GDKC-5000 Portable Transformer On Load Tap Changer Tester

Product Introduction

We constantly encourage employees to study more advanced technology to obtain high quality transformer tan delta tester, open cup flash point test equipment, wireless phasing sticks. Our company has established an organization management mode and project management mechanism suitable for our own development, which has made our company develop rapidly. Our company close to the market demand, according to its development trend, adhere to the principle of multi-level and serialization and form its own core competitiveness.

HZYA-3Z Transformer On Load Tap Changer Oltc Tester

The Transformer On-Load Tap Changer (OLTC) Parameter Tester is a specialized instrument designed for measuring and analyzing the operating characteristics of transformer on-load tap changers.

It can test key parameters of the on-load tap changer, including its transition process, transition waveform, transition time, transient resistance, and three-phase synchronism.

Transformer On Load Tap Changer Tester

Features

1. Large output current, light weight;

2. Test YO, Y, △ type transformer, the resistance unnecessary to be converted but directly display;

3. With winding or without winding measurement;

4. Waveform display automatically adjusts the resistance according to the sampled value, the time value amplitude

5. With perfect protection circuit, reliability and strong;

6. 7-inch large LCD display, easy on-site operation;

7. Built-in high-capacity lithium battery(optional)

8. 500 sets of data can be saved in Internal automatically, can connect with U Disk.

Technical Parameters


Output current

2.0A,1.0A,0.5A,0.2A

Measuring range Transition resistance

0.5Ω~5Ω(2.0A)/ 2Ω~20Ω(1.0A)/ 5Ω~40Ω(0.5A)/ 20Ω~100Ω(0.2A)

Transition time

0 ~ 320ms

Open circuit voltage

24V

Measurement accuracy Transition resistance

± (5% reading ± 0.1Ω)

Transition time

± (0.1% reading ± 0.2ms)

Sampling rate of 20kHz

Storage mode U disk storage

hzya-3z


lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image005

image007

Request for quote_

In the continuous communication with users, we constantly optimize the humanized design, function and overall design of our GDKC-5000 Portable Transformer On Load Tap Changer Tester. Relying on strong research and development strength, standardized management system, sophisticated production equipment and complete testing methods, our company has now developed into a diversified and group-oriented enterprise. We expect to quickly achieve industrial resource integration and scale expansion, and accelerate asset value realization.

Hot Tags: HZYA-3Z Transformer On Load Tap Changer Oltc Tester, China, suppliers, manufacturers, price, for sale, on load tap changer test of transformer, on-load tap changer testing methods, Transformer On Load Tap Changer Analyzer, transformer on load tapchanger analyser HZYA-3Z, On Load Tap Changer Analysis, onload tap changer test equipment, AC Withstand Voltage Test Van, six phase relay test equipment, SF6 Gas Purity Test Set, 6 phase relay testing, reid vapor pressure tester, underground cable fault pinpoint locator

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message