GDGS Automatic Transformer Insulation Power Factor Tester Tan Delta Test Set
Dielectric loss value of tested article tgδ is displayed with %.
Product Introduction
With efficient manufacturing capabilities, we ensure that the quality and supply capabilities of our transformer onno load loss tester, battery discharge capacity tester, petroleum colorimeter can always meet the dynamic requirements of the market. We invite you to visit our company for a personalized tour and advanced business guidance. We sincerely hope to join hands with new and old customers to create brilliant prospects.
HZ-2000B 10kV/12kV Automatic Tan Delta Test Kit Of Power Transformer






Testable Parameters
Capacitance value of tested article CX is in pF or nF, 1nF=1,000pF.
Dielectric loss value of tested article tgδ is displayed with %.

Performance Features
1. The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.
2. The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. So a reliable data will be reachable even under the strong electromagnetic interference.
3. The instrument adopts large screen LCD . In the process of testing, Chinese menu prompt is visualized and easy to operate.
4. The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.
5. The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.
7. The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.
8. GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.
9. The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.
10. The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 10kV with the help of voltage transformer or series resonance.
12. The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV. As for the over-current protection function, it will protect the instrument from damage when the tested article is in a short circuit or breakdowns.
13. The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock due to incaution, the instrument will cut off the HV immediately and thus ensure the security of operator.

Tech Data
Accuracy | Cx: ±(reading×1%+1pF) |
tgδ | ± (reading×1%+0.00040) |
Anti-interference | Variable frequency anti-interference, the above accuracy can be reached under 200% interference. |
Capacitance range | Internal HV 3pF~60000pF/10kV 60pF~1μF/0.5kV |
External HV | 3pF~1.5μF/10kV 60pF~30μF/0.5kV |
Resolution | Maximum 0.001pF, 4 valid figures. |
tgδ range | unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. |
Test current range | 10μA~1A |
Internal HV | Set voltage range: 0.5~10kV |
Maximum output current | 200mA |
Buck-bust method | Continuous stepless regulation |
Test frequency | 45, 50, 55 single frequency, 45/55Hz automatic dual variable frequency |
Frequency accuracy | ±0.01Hz |
Printer | WH-A7 mini-type thermal printer |
Environment temperature | -10℃~50℃ |
Relative humidity | <90% |
Overall dimension | 460×360×350mm |
Weight | 28kg |



For a long time, the company has established an excellent management team integrating design, production and marketing with the GDGS Automatic Transformer Insulation Power Factor Tester Tan Delta Test Set industry as the pillar, market demand as the pillar, and marketing outlets all over the country. . We attach importance to and strive to cultivate excellent talents, so that talents become the core competitiveness of the company. After our efforts in Entrepreneurship and concerted development, we are now standing on the high ground of the industry and continuing to explore and innovate.
Hot Tags: HZ-2000B Automatic Transformer Tan Delta Test Kit, China, suppliers, manufacturers, price, for sale, 12 kv tan delta test kit for transformer, tan delta test kit price in india, tan delta test kit manual, tan delta testing of power transformer, Capacitance and Tan delta kit, tan delta testing kit 12 kv HZ-2000B, tan delta test kit specification, tan delta test kit manufacturers in india, Tan Delta Tester of bushing & winding, C-tan delta kit, closed cup flashpoint tester, manual distillation apparatus, kf titrator, primary current injection test set manual, lubricating oil abrasion wear tester, Karl Fischer Moisture Analyzer