Gd-264b ASTM D664 Automatic Transformer Oil Acid Value Tester
Product Introduction
Our company has a professional technical service team, self-developed transformer winding deformation tester, Pour Point Tester, six phase protection relay test set, at the same time can provide customers with meticulous service. In order to meet the application needs, improve the cost performance of products, deepen the cooperation with customers, we always adhere to the customer first. Our company has strong technical force, reasonable equipment and technology, complete product production and quality assurance system and perfect after-sales service. We have established our corporate mission, vision and entrepreneurial spirit as fundamental principles and philosophies that we believe in and uphold in our relationships with our customers, employees and other stakeholders.
HZCS-3 Transformer Oil Total Acid Number Tester
Summary
HZCS-3 Transformer Oil Acid Tester is a fully automated measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The instrument will automatically search the samples, inject the extraction, make a blank titration, do an experiment, clean off, display printing results and other operations as long as the operator put the sample cups in the sample cup holes and inject the extraction in the cup. Once started, 1 to 3 samples can be measured, which is convenient and high efficiency.
Tech Index
|
Test range |
0.002~1mg KOH/g |
|
Test error |
≤±0.005mg KOH/g |
|
Repeatability |
≤0.005mg KOH/g |
|
Ambient temperature |
10℃~45℃ |
Operation Notice
1. The peristaltic pump hose is easy to wear. Please check whether the hose is damaged or adhesion carefully to reduce the impact on the instrument.If there is any abnormal, replace the hose. After the instrument finished, please release the squeeze arm of the peristaltic pump to prevent the peristaltic pump hose from being damaged by the arm.
2. It is recommended to re-calibrate with standard acid if the instrument is not used for more than three months.
3. When preparing the extract, the container must be dry and cannot have water. The extract is sealed and stored.
4. When the test is continuous, it is allowed that the cup cannot be cleaned. If not, the cup must be cleaned and the sample cups should be completely dry before use.
5. After the test must be cleaned off.
Packing List
|
No. |
Item |
Qty |
|
1 |
Main engine |
1 |
|
2 |
Neutralization liquid medicine |
2 |
|
3 |
Extracted liquid medicine |
2 |
|
4 |
Gas washing bottle medicine |
1 |
|
5 |
Indicator |
1 |
|
6 |
Standard acid |
1 |
|
7 |
Microsyringe |
1 |
|
8 |
Sample cup |
4 |
|
9 |
Stirrer |
5 |
|
10 |
Glass bottle |
3 |
|
11 |
Glass bottle cap |
3 |
|
12 |
Tubing for Peristaltic Pumps |
1 |
|
13 |
Print paper |
2 |
|
14 |
Power line |
1 |
With the diversified marketing mode, we can provide you with the best Gd-264b ASTM D664 Automatic Transformer Oil Acid Value Tester solution according to the different needs of customers. Through the excellent performance management model, we gradually improve the modern human resource management system and strengthen management innovation. We keep our mission in mind with gratitude, and do not forget our original intention.
Hot Tags: HZCS-3 Transformer Oil Total Acid Number Tester, China, suppliers, manufacturers, price, for sale, petroleum products acid number tester, oil acid value test machine, transformer oil testing photos, Automatic Insulation Oil Acid Tester, total acid number oil analyzer, hzcs-3 total acid number oil analysis test kit, hzcs3, lubricants total acid number tester, automatic oleic acid tester, transformer vacuum oil purifier, asphalt wax content tester, high voltage multifunction phasing stick, oil tan delta test set, Sf6 Gas Leak test, cable identificator