Fully Automatic Petroleum Products Total Acid Number Tester
Product Introduction
Our Transformer Oil Purifier, High Voltage AC Test Transformer, 3 Phase Primary Current Injection Test Set have been used by the majority of users for many years, with reliable quality, stable performance and good reputation. With our strong global sourcing network and close cooperation with established suppliers, we can provide customers with high-quality products and take the interests and satisfaction of customers as our top priority. So far, our business has been expanding, our economic scale has been expanding, and our business performance has been improving. We hope to further unite the struggling spirit of our employees and lead and promote the sustainable and healthy development of the company.
HZCS-3 Transformer Oil Total Acid Number Tester
Summary
HZCS-3 Transformer Oil Acid Tester is a fully automated measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The instrument will automatically search the samples, inject the extraction, make a blank titration, do an experiment, clean off, display printing results and other operations as long as the operator put the sample cups in the sample cup holes and inject the extraction in the cup. Once started, 1 to 3 samples can be measured, which is convenient and high efficiency.
Tech Index
|
Test range |
0.002~1mg KOH/g |
|
Test error |
≤±0.005mg KOH/g |
|
Repeatability |
≤0.005mg KOH/g |
|
Ambient temperature |
10℃~45℃ |
Operation Notice
1. The peristaltic pump hose is easy to wear. Please check whether the hose is damaged or adhesion carefully to reduce the impact on the instrument.If there is any abnormal, replace the hose. After the instrument finished, please release the squeeze arm of the peristaltic pump to prevent the peristaltic pump hose from being damaged by the arm.
2. It is recommended to re-calibrate with standard acid if the instrument is not used for more than three months.
3. When preparing the extract, the container must be dry and cannot have water. The extract is sealed and stored.
4. When the test is continuous, it is allowed that the cup cannot be cleaned. If not, the cup must be cleaned and the sample cups should be completely dry before use.
5. After the test must be cleaned off.
Packing List
|
No. |
Item |
Qty |
|
1 |
Main engine |
1 |
|
2 |
Neutralization liquid medicine |
2 |
|
3 |
Extracted liquid medicine |
2 |
|
4 |
Gas washing bottle medicine |
1 |
|
5 |
Indicator |
1 |
|
6 |
Standard acid |
1 |
|
7 |
Microsyringe |
1 |
|
8 |
Sample cup |
4 |
|
9 |
Stirrer |
5 |
|
10 |
Glass bottle |
3 |
|
11 |
Glass bottle cap |
3 |
|
12 |
Tubing for Peristaltic Pumps |
1 |
|
13 |
Print paper |
2 |
|
14 |
Power line |
1 |
As always, we will sell the best cost-effective Fully Automatic Petroleum Products Total Acid Number Tester with the best quality, and offer the most attentive service to you. It is well highly acclaimed by our customers. We maintain timely delivery schedules, innovative designs, quality and transparency for our customers.
Hot Tags: HZCS-3 Transformer Oil Total Acid Number Tester, China, suppliers, manufacturers, price, for sale, petroleum products acid number tester, oil acid value test machine, transformer oil testing photos, Automatic Insulation Oil Acid Tester, total acid number oil analyzer, hzcs-3 total acid number oil analysis test kit, hzcs3, lubricants total acid number tester, automatic oleic acid tester, cable fault pinpoint locator, turns ratio test equipment, 3 phase turn ratio test set, sound level meter, distribution transformer test bench, tan delta test set