Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set
Dielectric loss value of tested article tgδ is displayed with %.
Product Introduction
Our highest value orientation is to create a high-quality staff full of care for human and nature, and to create the best quality DC Hipot Test Machine, primary current injection test machine, sf6 gas quantitative leak detector. We insist on steady management, developing and growing industry, and insisting on being an enterprise with a strong sense of social responsibility and mission. It is difficult for an enterprise to be strong, and it is even more difficult to maintain its prosperity; what matters is not an individual, some people, but all the people, that is, every cell is full of vitality. We will speed up the adjustment and upgrading of product structure and use high and new technology to transform and upgrade traditional industries as an entry point to accelerate the development of high-tech industries. Our company advocates a corporate culture of unity, innovation, and people-oriented.
HZ-2000B 10kV/12kV Automatic Tan Delta Test Kit Of Power Transformer






Testable Parameters
Capacitance value of tested article CX is in pF or nF, 1nF=1,000pF.
Dielectric loss value of tested article tgδ is displayed with %.

Performance Features
1. The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.
2. The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. So a reliable data will be reachable even under the strong electromagnetic interference.
3. The instrument adopts large screen LCD . In the process of testing, Chinese menu prompt is visualized and easy to operate.
4. The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.
5. The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.
7. The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.
8. GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.
9. The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.
10. The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 10kV with the help of voltage transformer or series resonance.
12. The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV. As for the over-current protection function, it will protect the instrument from damage when the tested article is in a short circuit or breakdowns.
13. The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock due to incaution, the instrument will cut off the HV immediately and thus ensure the security of operator.

Tech Data
Accuracy | Cx: ±(reading×1%+1pF) |
tgδ | ± (reading×1%+0.00040) |
Anti-interference | Variable frequency anti-interference, the above accuracy can be reached under 200% interference. |
Capacitance range | Internal HV 3pF~60000pF/10kV 60pF~1μF/0.5kV |
External HV | 3pF~1.5μF/10kV 60pF~30μF/0.5kV |
Resolution | Maximum 0.001pF, 4 valid figures. |
tgδ range | unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. |
Test current range | 10μA~1A |
Internal HV | Set voltage range: 0.5~10kV |
Maximum output current | 200mA |
Buck-bust method | Continuous stepless regulation |
Test frequency | 45, 50, 55 single frequency, 45/55Hz automatic dual variable frequency |
Frequency accuracy | ±0.01Hz |
Printer | WH-A7 mini-type thermal printer |
Environment temperature | -10℃~50℃ |
Relative humidity | <90% |
Overall dimension | 460×360×350mm |
Weight | 28kg |



Since we use standard assembly line production equipment, our Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set is more formal, reliable in quality and inexpensive. Our talent concept is to rationally control the scale, optimize the team structure, innovate the development mechanism, and stimulate talent potential. We are engaged in a great and arduous business, the development of which requires the long-term and unremitting joint efforts of all employees.
Hot Tags: HZ-2000B Automatic Transformer Tan Delta Test Kit, China, suppliers, manufacturers, price, for sale, 12 kv tan delta test kit for transformer, tan delta test kit price in india, tan delta test kit manual, tan delta testing of power transformer, Capacitance and Tan delta kit, tan delta testing kit 12 kv HZ-2000B, tan delta test kit specification, tan delta test kit manufacturers in india, Tan Delta Tester of bushing & winding, C-tan delta kit, variable inductance resonant test system, generator partial discharge test device, surge arrester test set, transformer onno load loss tester, ac test transformer 50kv, Pour Point Tester
[[ProKeywords]]SPEC DATA