Ddg China Price High Precision 10000AMP Primary Current Injection Test Kit
Product Introduction
To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for single stage vacuum transformer oil purifier, primary current injection test, oil flash point testing machine. We hope that each employee will finish each job well and be responsible for our customers and the company. Our company has introduced and trained a number of high-quality professional and technical personnel and management personnel, and established a perfect quality management system.
HZ-109S 1000A Primary Current Injection Test Set

Overview
The HZ-109S Primary Current Injection Test Set utilizes ARM chip control technology for output management and a high-capacity toroidal transformer. Equipped with an LCD display meter, it can simultaneously display the primary current, secondary current, turn ratio, and the actuation time of the stopwatch connection (electric potential). Housed in an external aluminum alloy case with a PC panel, the product offers a nice appearance, large output capacity, small size, and light weight. It is primarily suited for CT turn ratio tests, contact resistance tests, and other applications requiring high-current testing in power systems.





The Technology Index
Input Power Supply | AC: 220V· 25A, 50Hz. |
Output Current | AC: 1000A·5V or 500A·10V. |
LCD Screen Digital Display | Simultaneous display of primary current and secondary current as well as the turn ratio; |
The Range of Primary Current | 0~1100A, Resolution: 0.1A; |
The Range of Secondary Current | 0~6A; Resolution: 0.001A. |
Stopwatch | 0.0001~999.99S precision ±5 significant figures. |
Precision | TRUE RMS ±0.5%. |
Duplicate Protection (electronic overload protection and software protection). | |
Usage Environment | Temperature -10~40℃, |
Relative humidity | <80%. |
Volume | 430×260×260mm3. |
Weight | 28kg. |

Safety Precautions
1. In order to ensure the safe operation of test, the instrument should be grounded reliably before the test.
2. The power supply voltage should be set as 220V±10%. Do not input 380V power supply into the instrument, or the instrument will be severely damaged.
3. Connecting or disconnecting the test wire is strictly prohibited when the test is conducting.
4. For the test set, the cable cross-section of input power should be greater than 2mm2, and the cable cross-section of high current output connection should be greater than 70mm2, and the cable length of the output connection should be kept as short as possible.
5. Use paralleling output wherever possible, if only the demand of output current is met.
6. Avoid continuous output in a long time.



Our business goal is: brand is not the best, only better, we pursue the perfection of Ddg China Price High Precision 10000AMP Primary Current Injection Test Kit endlessly. As a company pursuing excellence, we not only provide customers with world-class products and services, but also actively assume social responsibility and be an excellent corporate citizen. We have a cooperative technical team and a perfect after-sales service system.
Hot Tags: HZ-109S 1000A Primary Current Injection Test Set, China, suppliers, manufacturers, price, for sale, high current circuit breaker test set, Primary Current Injection Test Setup, Primary Injection Test Set 1000 amp HZ-109S, programma primary injection test set, primary current injection for relay test set, HZ109S, 1000a generation current, high current injection test 1000a, transformer testing equipment, transformer dc resistance tester, reid vapor pressure tester, dga test of transformer oil, dc hipot test 120kv, handhled surge arrester discharge counter tester