DC/AC Resistive/Inductive/Capacitive/Reactive Dummy Load Bank for UPS & Generator Test
Product Introduction
The company is serious and rigorous, meticulously transcends, and dedicated, will adhere to the service-based and quality-based business philosophy; through R&D and innovation, we will continue to provide customers with more high-quality and low-cost intelligent production equipment; strive to become a global The most famous sf6 gas leak detector, ac test transformer 50kv, oil tan delta test set supplier service provider. They're about to make it possible for you to get complete acknowledge about our things and make a satisfied negotiation. The spirit of enterprise is serious, hardworking, sincere and goodwill, and the code of conduct is to be a good person, do good things, work with a career attitude, have a strong sense of responsibility and enterprising spirit, and be diligent in learning. Facing the new normal of economic development, we carry out the development strategy of pragmatic development, optimization of manufacturing and research of growth points.
HZFD-200 Battery Load Bank Discharge Tester
CE Certificate






Introduction
The DC load bank is a specialized instrument designed for testing Ni-Cd and lead-acid storage battery strings in communication facilities. It supports whole-string voltage testing for 24 V, 48 V, 110 V, and 220 V battery banks, as well as individual cell voltage testing for 1.2 V, 2 V, 6 V, and 12 V cells.
Utilizing advanced testing technology, the instrument incorporates breakthroughs in new techniques, components, materials, and processes. It is designed in accordance with national testing and maintenance regulations, making it a specialized tool for stationary battery performance evaluation.
With high discharge power, compact size, light weight, and comprehensive PC-based data management software, the battery load bank significantly reduces the workload associated with daily testing and maintenance of stationary batteries.

Applicable battery | Lead-acid battery | |
Output voltage | 110V | 220V |
Output current | 0-180A | 0-90A |
Operating mode | Used independently or with a constant-current module | |
Protection performance | Input terminal overvoltage protection, prompts on the LCD; | |
Single battery voltage acquisition | The 433RF wireless module supports a communication distance longer than 100 m and monitoring for single battery voltages of 2V, 4V, 6V and 12V. If the total voltage is not beyond the set value, each battery pack will have an unlimited single battery quantity and can monitor one to sixteen RF wireless monitoring modules at the same time. One RF wireless monitoring module can monitor 12 single batteries at the same time. | |
Control accuracy | Discharge current: ≤±1%; battery pack's terminal voltage: ≤ ±0.1%; single battery voltage: ≤±0.05% | |
Communication with the host PC | RS485 interface | |
Data storage capacity | 2Gbit FLASH | |
Operating conditions | ||
Cooling | Forced air cooling | |
Temperature | Operating temperature: -5~50℃; storage temperature: -40~70℃ | |
Humidity | Relative humidity: 0~90% (40±2℃) | |
altitude | Rated altitude: 4,000 m | |
Noise | ﹤60dB | |
Operating power supply | ||
Voltage | Single-phase three-wire system: 220V AC (–20%~+30%); frequency: 45~65Hz; | |
Withstand voltage test | Input--casing: 2200Vdc 1min | |
Wiring | ||
AC output | Male socket in line with the applicable national standard, applicable to 1~1.5mm2 cable | |
DC output | 25mm2 cable quick plug (red: positive; black: negative) | |
After-sales Service
Within one year from the date of purchase, any quality issues caused by the company will be covered by free maintenance. Lifelong maintenance and technical support are also provided.
If any abnormality or malfunction is detected during use, please contact the company promptly. We will arrange the most convenient solution and provide the fastest on-site service to address your needs.



Since our establishment, we have been adhering to the business philosophy of 'pioneering and innovative, honesty and win-win', committed to becoming a core company in the field of DC/AC Resistive/Inductive/Capacitive/Reactive Dummy Load Bank for UPS & Generator Test. At present, we are committed to integration, creating value, accelerating team building, opening up and achieving win-win results. Our service team can provide professional services in the shortest time to help customers solve problems in a timely manner.
Hot Tags: HZFD-200 DC Load Bank Battery Discharge Tester, China, suppliers, manufacturers, price, for sale, 48vdc load bank, Battery Discharge Machibe 48V 200A, battery load bank testing, battery discharger & capacity tester, Battery Discharge Test Kit, dc loadbank, hzfd-200, battery discharge tester 12v 24v, high current battery load tester, detection battery discharger, battery load unit 200vdc, battery tester load 300a, capacitance and tan delta meter, cable fault locator huazeng, closed cup flash point analyzer, partial discharge free test system, transformer capacity and loss tester, dc system earth fault tester
[[ProKeywords]]SPEC DATA
Send Inquiry