DC 100A Contact Resistance Meter Continuously Output High Current with Printer
Product Introduction
We are always striving to achieve product excellence in order to provide our customers with best sf6 gas leak tester, pour point testing machine, empty load loss parameter tester and all-round service. Our company is an enterprise full of vitality, aggressiveness and broad development space. We can provide the products you want. We are committed to business development and technological innovation, pursuing comprehensive quality management, and fulfilling corporate social responsibility. We are the ideal partner of your business development and look forward to your sincere cooperation.
HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer
high-voltage circuit breaker analyzer is suitable for mechanical characteristic testing of SF6 switches, GIS composite electrical appliances, vacuum switches, and oil switches.

High Voltage Circuit Breaker Analyzer Precautions
1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
2. The connect action of the test lines should be done before supply power to the instrument.
3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.
4. Try to use the special test leads and accessories provided by this instrument.
5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.
6. Avoid using it in humid, flammable and explosive environments.
7. The power supply of the instrument is 220V AC, and 380V is prohibited.





High Voltage Circuit Breaker Analyzer Technical Characteristics
Test channels | 12 channels with 25V, the current is 50mA |
Transducer | One analog transducer. |
TIME | |
Recording time length | 0~20.0s |
Time accuracy | ±0.l%reading ± 2 LSB |
Resolution | 0.1ms |
Motion | |
Range | 0~1000mm |
Accuracy | ±1% reading ±1LSB |
Resolution | 0.1mm |
Velocity | |
Ranges | 0.01~20.00m/s |
Accuracy | ±1%reading ±1LSB |
Resolution | 0.01m/s |
DC POWER | |
Ranges | 5~260V |
Max current | 20A |
Accuracy | ±1%reading ±1LSB |
Load change | ≤1% |
TRIGGER | |
Voltage | 5~260V |
Current | 0.1-20A |
Transducer | The transducer states changes |
Channels | Channels states changed |
DIMENSIONS | 415mm×320mm×168mm |
WEIGHT | 8kg |
OPERATION TEMPERATURE | -10℃~50℃ |
HUMIDITY | ≤80% RH |
POWER SUPPLY | |
Voltage | AC 220V±10% |
FREQUENCE | 50Hz±10% |
SAFETY | |
Insulation resistance | >2MΩ |
Leakage current | <3.5mA |
Immunity | AC 1500V 50Hz, 1min. |



With the rapid development of the industry, our company continues to study and master the key technologies and develop DC 100A Contact Resistance Meter Continuously Output High Current with Printer with independent intellectual property rights. We are determined to 'high precision, high quality, high standard' products to repay new and old customers for our recognition. We are willing to advanced technology, high-quality products, preferential prices, satisfactory service, looking forward to sincere cooperation with you to create a better future!
Hot Tags: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system, CB dynamic mechanical analyzer, Transformer Capacity Tester, surface tension test machine, oil color test kit, transformer test instrument, transformer oil test machine, capacitive voltage divider
[[ProKeywords]]SPEC DATA
Send Inquiry