Centrifugal Turbine Hydraulic Oil Filtration Machine/Transformer Oil Cleaning Purifying Machine/Engine Oil Filter Machine/Waste Oil Recycling Regeneration
Product Introduction
We give full play to our technological advantages and directly transform advanced scientific and technological achievements into the dc resistance meter, 1 phase relay test set, hipot test transformer for production practice. We keep abreast of market trends at home and abroad with a keen eye, and develop new products with the times. We actively respond to the country's development strategy and actively expand overseas markets in the context of fierce domestic market competition. We adhere to the service tenet of 'providing personalized products to meet individual needs' and strive to meet the needs of all users.
2000L/H Used Waste Lubricant Oil Recycling Machine
I. Parameter
Model: HZLY-35A
Nominal flow: 2000L/h
Net oil capacity: 33L/min
Pumping rate: 252M³/h
Ultimate vacuum: ≤10Pa
Working pressure: ≤0.5Mpa
Working oil temperature:20~80℃
Working power supply: 50Hz 380V three-phase three-wire
Heating power: 30kW (Separate control by two groups)
Total power: 36kW
Operating noise: ≤75dB(A)
Inlet/outlet flange: DN25
Vacuum interface flange: DN25
Dimensions: 150×145×150cm
Equipment weight: 560Kg
Continuous working time: ≥200 hours
Average trouble-free working time:≥ 5000 hours
II.Main Spare Parts
No | Name | Function | Note |
MV01 | Outlet oil valve | Control oil outlet | |
MV02 | Inlet oil valve | Control oil inlet | |
MV03 | Outlet oil valve | Control oil outlet | |
MV04 | Inlet oil valve | Control oil inlet | |
MV07 | Gulp valve | Replenish degassing chamber air when stopping or repairing | |
MV09 | Sampling valve | Oil sample after treatment | |
MV10~14 | Emptying valve | Empty oil of oil container | |
CV01~03 | Single direction valve | One-way oil delivery to prevent oil backflow. | |
FL01 | Primary filter | Remove large particles | |
FL02 | Secondary filter | Remove the impurities above 3µm | |
FL03 | Third filter | Remove the impurities above 1µm | |
FL04 | Air filter | Filtered air particle | |
SV01 | Main oil inlet solenoid valve | Main valve of liquid level | |
SV02 | second oil inlet solenoid valve | Second valve of liquid level | |
FS01 | Heating liquid level sensor | Collect the liquid level signal of the heater | |
FS02 | liquid level sensor | Collect the signal of liquid level | |
FS03 | liquid level sensor | Collect the signal of liquid level | |
FS04 | Condenser high level sensor | Collect the condenser liquid level signal | Anti-injection protection |
FS05 | Condenser low level sensor | Collect the condenser liquid level signal | |
PES | High level sensor | Collect high level signal | Anti-injection protection |
PT01 | Filter pressure sensor | Collect filtered pressure signal | optional |
PT02 | Vacuum pressure sensor | Collect vacuum pressure signal | optional |
TT01 | Temperature sensor | Collect oil temperature signal | |
PS01 | Pressure switch | High pressure protection of oil chamber | |
VG01 | Vacuum gauge | Show the vacuum degree of degassing chamber | |
PG01 | Pressure meter | Display filter pressure | |
HT | Heater | heating | |
P01 | Vacuum pump | Primary vacuum | |
P02 | oil transfer pump | Drain the oil from the vacuum chamber | |
P03 | Roots pump | Second vacuum | |
P04 | Oil inlet pump | Control oil | optional |
Evaporator | Vacuum chamber | Remove oil & gas | |
OGS | Oil and gas separator | Separate the oil engine gas | |
BFE | Foam Eliminator | Pressurize the foam and turn it into oil | |
Buffer | Buffer | ReStore oil temporarily |
Configurations
NO | Name | Model | Qty |
1 | Vacuum pump | X-40 | 1 |
2 | Roots pump | ZJP-70 | 1 |
3 | Oil drain pump | CBY2040-1FL | 1 |
4 | Coarse filter | A050 | 1 |
5 | Primary filter | 5µ | 1 |
6 | Second filter | 1µ | 1 |
7 | Heater | 10kW | 3 |
8 | Ball valve | DN25 stainless steel | 2 |
9 | Check valve | DN25 | 1 |
10 | valve | DN15F | 7 |
11 | Solenoid valve | DN15 | 2 |
12 | Electric | DELIXI | 1 |
13 | PLC | S7-200 | 1 |
14 | Text screen | OP325 | 1 |
15 | Liquid level sensor | GMF-80SI-2A2 | 1 |
16 | Liquid level sensor | GMF-80SI-2A2 | 4 |
17 | Pressure sensor | KP36 | 1 |
18 | Electronic vacuum gauge (optional) | TTR91 | 1 |
19 | Water sensor (optional) | EE364 | 1 |
20 | Flowmeter (optional) | DN20 | 1 |
21 | Atomizer | BB3/8BRASS-12W | 1 |
22 | Degassing chamber | VV6001500 | 1 |
23 | Seal | 25-215*4 | 1 |
24 | Electrical control box | C600 | 1 |
III. Index after treatment
Oil to be treated
Breakdown voltage: >30kV (bulb);
Water content: ≤50ppm;
Gas content: ≤10% (volume ratio);
After a process
Breakdown voltage: >70kV (bulb);
Water content: ≤5ppm;
Gas content: ≤0.2% (volume ratio);
Three or four processes later
Breakdown voltage: >80kV (bulb);
Water content: ≤3ppm;
Gas content≤0.1% (volume ratio);
Acetylene content: 0



We manufacture a large range of standard Centrifugal Turbine Hydraulic Oil Filtration Machine/Transformer Oil Cleaning Purifying Machine/Engine Oil Filter Machine/Waste Oil Recycling Regeneration and in addition, we have a team of engineers and production experts who can also customize the products as per the requirements of the customers. Innovation requires us to transcend ourselves and promote the sustainable development of the enterprise with comprehensive innovation of system, mechanism, management and technology. We have a professional product development and design team to ensure that it can be customized according to the process needs of our customers.
Hot Tags: 2000l/h used waste lubricant oil recycling machine, China, suppliers, manufacturers, price, for sale, used motor oil recycling machines, used engine oil recycling machine, machine transformer oil recycling equipment, HZLY-35A, megohmmeter 20kv, filter machine for transformer oil, open cup flash point test machine, High Voltage AC Test Transformer, sf6 gas leakage detection equipment, reid vapour pressure apparatus
[[ProKeywords]]SPEC DATA