Best Price High Voltage Switch Dynamic Characteristics Circuit Breaker Tester
Product Introduction
We are confident that it is possible to gain market share since we have such a excellent lead acid battery discharger, three phase transformer turns ratio meter, transformer oil bdv test equipment combined with a good understanding of customers' needs. We adhere to the focus strategy, continuous R&D investment in the field, customer needs and cutting-edge technology-driven innovation. We have many years of industry experience and quality is guaranteed We are committed to becoming a sustainable enterprise and therefore fully implement a green and low-carbon development strategy.
HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer
high-voltage circuit breaker analyzer is suitable for mechanical characteristic testing of SF6 switches, GIS composite electrical appliances, vacuum switches, and oil switches.

High Voltage Circuit Breaker Analyzer Precautions
1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
2. The connect action of the test lines should be done before supply power to the instrument.
3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.
4. Try to use the special test leads and accessories provided by this instrument.
5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.
6. Avoid using it in humid, flammable and explosive environments.
7. The power supply of the instrument is 220V AC, and 380V is prohibited.





High Voltage Circuit Breaker Analyzer Technical Characteristics
Test channels | 12 channels with 25V, the current is 50mA |
Transducer | One analog transducer. |
TIME | |
Recording time length | 0~20.0s |
Time accuracy | ±0.l%reading ± 2 LSB |
Resolution | 0.1ms |
Motion | |
Range | 0~1000mm |
Accuracy | ±1% reading ±1LSB |
Resolution | 0.1mm |
Velocity | |
Ranges | 0.01~20.00m/s |
Accuracy | ±1%reading ±1LSB |
Resolution | 0.01m/s |
DC POWER | |
Ranges | 5~260V |
Max current | 20A |
Accuracy | ±1%reading ±1LSB |
Load change | ≤1% |
TRIGGER | |
Voltage | 5~260V |
Current | 0.1-20A |
Transducer | The transducer states changes |
Channels | Channels states changed |
DIMENSIONS | 415mm×320mm×168mm |
WEIGHT | 8kg |
OPERATION TEMPERATURE | -10℃~50℃ |
HUMIDITY | ≤80% RH |
POWER SUPPLY | |
Voltage | AC 220V±10% |
FREQUENCE | 50Hz±10% |
SAFETY | |
Insulation resistance | >2MΩ |
Leakage current | <3.5mA |
Immunity | AC 1500V 50Hz, 1min. |



Relying on advanced production equipment system, we realize standardized operation and provide users with high-quality Best Price High Voltage Switch Dynamic Characteristics Circuit Breaker Tester in the shortest time. In today's increasingly fierce market competition, we are working hard to develop new products and new technologies in order to meet the ever-changing needs of users. We do our best to provide our employees with a talented and humane leadership group and a clean and safe working environment.
Hot Tags: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system, CB dynamic mechanical analyzer, portable petroleum products viscosimeter, Relay Test System, hv surge arrester testing, oil abrasion tester, primary current injection test system, astm d86 distillation tester