+86-312-6775656
Automatic Capacitance & Dielectric Loss Tester C&Df Test Kit Tan Delta Test Set

Automatic Capacitance & Dielectric Loss Tester C&Df Test Kit Tan Delta Test Set

Capacitance value of tested article CX is in pF or nF, 1nF=1,000pF.
Dielectric loss value of tested article tgδ is displayed with %.
Send Inquiry
Product Details of Automatic Capacitance & Dielectric Loss Tester C&Df Test Kit Tan Delta Test Set

Product Introduction

The quality of Sweep Frequency Response Analyzer, phasing stick 11kv, 6 phase secondary injection relay test set is strictly controlled, and they have undergone strict aging and testing procedures before leaving the factory. Our purpose would be to offer good quality products at competitive price ranges, and top-notch support to clients around the whole world. Our company innovates unceasingly, strives to create the first-class enterprise and invites the distinguished guests from all walks of life, new and old friends to visit and guide. Business management talents play an important role in the survival and development of enterprises.

HZ-2000B 10kV/12kV Automatic Tan Delta Test Kit Of Power Transformer

Tan Delta Test Kit price (1)

Tan Delta Test Kit price (2)

Tan Delta Test Kit price (4)

Tan Delta Test Kit price (5)

HZ-2000B_03


Tan Delta Tester

Testable Parameters

Capacitance value of tested article CX is in pF or nF, 1nF=1,000pF.

Dielectric loss value of tested article tgδ is displayed with %.

image002

Performance Features

1. The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.

2. The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. So a reliable data will be reachable even under the strong electromagnetic interference.

3. The instrument adopts large screen LCD . In the process of testing, Chinese menu prompt is visualized and easy to operate.

4. The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.

5. The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.

7. The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.

8. GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.

9. The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.

10. The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 10kV with the help of voltage transformer or series resonance.

12. The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV. As for the over-current protection function, it will protect the instrument from damage when the tested article is in a short circuit or breakdowns.

13. The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock due to incaution, the instrument will cut off the HV immediately and thus ensure the security of operator.

image004

Tech Data

Accuracy

Cx: ±(reading×1%+1pF)

tgδ

± (reading×1%+0.00040)

Anti-interference

Variable frequency anti-interference, the above accuracy can be reached under 200% interference.

Capacitance range

Internal HV 3pF~60000pF/10kV 60pF~1μF/0.5kV

External HV

3pF~1.5μF/10kV 60pF~30μF/0.5kV

Resolution

Maximum 0.001pF, 4 valid figures.

tgδ range

unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles.

Test current range

10μA~1A

Internal HV

Set voltage range: 0.5~10kV

Maximum output current

200mA

Buck-bust method

Continuous stepless regulation

Test frequency

45, 50, 55 single frequency, 45/55Hz automatic dual variable frequency

Frequency accuracy

±0.01Hz

Printer

WH-A7 mini-type thermal printer

Environment temperature

-10℃~50℃

Relative humidity

<90%

Overall dimension

460×360×350mm

Weight

28kg

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image007

image009

Request for quote_

With advanced equipment and superb craftsmanship, we focus on the development and production of Automatic Capacitance & Dielectric Loss Tester C&Df Test Kit Tan Delta Test Set, and strive to meet the different needs of users through continuous practice and innovation. Over the years, we have adhered to technology, management, talent system and cultural innovation, and continuously achieved new breakthroughs in products. We pay attention to the business opportunities of working with you, and cherish the long-term friendship established in cooperation. We sincerely look forward to working together with new and old customers and people from all walks of life to achieve a better future!

Hot Tags: HZ-2000B Automatic Transformer Tan Delta Test Kit, China, suppliers, manufacturers, price, for sale, 12 kv tan delta test kit for transformer, tan delta test kit price in india, tan delta test kit manual, tan delta testing of power transformer, Capacitance and Tan delta kit, tan delta testing kit 12 kv HZ-2000B, tan delta test kit specification, tan delta test kit manufacturers in india, Tan Delta Tester of bushing & winding, C-tan delta kit, threephase relay protection tester, Transformer Oil BDV Tester, transformer oil dielectric strenth meter, 40A Winding Resistance Tester, primary current injection test set 3000a, pour point testing machine

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message