+86-312-6775656
ASTM D92 Automatic Cleveland Open Cup Flash Point and Fire Point Apparatus

ASTM D92 Automatic Cleveland Open Cup Flash Point and Fire Point Apparatus

Flash Point is the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material.
Send Inquiry
Product Details of ASTM D92 Automatic Cleveland Open Cup Flash Point and Fire Point Apparatus

Product Introduction

We always take 'quality as the core and customer satisfaction as the goal' as the company's guiding principle and create high-quality SF6 Gas Analyzer, sf6 gas purity test, ASTM d86 Distillation Test Equipment. We will continue to improve ourselves while bringing competitive products and services to customers. Thanks to the trust of our valued customers, we will continue working with our respectful customers with quick response, providing durable products, reliable quality and affordable price! Our aim is to provide you with the most affordable service in the market. We've optimised our business processes and minimised our overheads to do so, and we are constantly upgrading and optimising to bring you more.

HZKS-3 Automatic Cleveland Open Cup Flash Point Apparatus

Product Overview

The Automatic Cleveland Open Cup Flash Point Apparatus are suitable for the determination of petroleum products according to the standard petroleum products flash point and ignition point determination method (Cleveland open cup method) except for fuel oil and petroleum products with open flash point lower than 79℃.

The instrument is designed as a table-top structure, with stainless steel working table and stainless steel heating furnace shell, which is beautiful and elegant. The Automatic Cleveland Open Cup Flash Point Apparatus are equipped with flame extinguishing cover, which meets the requirements of the ignition point test.

Features

We believe that our Automatic Cleveland Open Cup Flash Point Apparatus can compete with any other similar products in terms of quality performance as well as price. It adopts a special heating furnace form to ensure the safety of the test. And its heating power is continuously adjustable to meet the requirements of the test. In addition, the instrument is complete, the user only needs to match the gas or other civil gas can be tested, it is very simple and convenient to use.

HZKS-3 Automatic COC Cleveland Open Cup Flash Point Apparatus

Cleveland Open Cup Flash Point Apparatus

Technical Parameters

Temperature Measurement

Temperature measuring range

-59.9°C~399.9°C

Temperature Control Range

Room temperature~400°C

Repeatability

≤150℃ 3℃, >150℃ 5℃

Resolution

0.1°C

Precision

0.5%

Temperature Sensor

Platinum Resistor(PT100)

Flash Fire Sensor

Ion detection ring

Ambient Temperature

0 ~ 40°C

Relative Humidity

≤ 85% RH

Power Supply

AC220V ± 20%; 50HZ ± 10%

Power Consumption

Approx 400W

Overall Dimension

440X280X290(mm)

Instrument Weight

14kg

Failure And Treatment

NO.

Failure

Treatment

1

Turn on the power, the LCD screen no display

Check power supply is plugged in, open the instrument measured the board examines the plug is not loose.

2

Large repeatability error for sample testing

Remove the lifting arm top cover, and check
1. whether the mixer shaft is broken
2. Oil may affect thermocouple sensitivity, plz dry it with filter paper

3

No heating

Electric wire broken

4

Lift arm rise or fall failure

Limit opt coupler damage
The screw between the main engine and lift arm fell off

Cleveland Open Cup Flash Point Apparatus

Cleveland Open Cup Flash Point Apparatus

Cleveland Open Cup Flash Point Apparatus

Cleveland Open Cup Flash Point Apparatus

HZKS-3_03

huazheng company info

image014

image016

Request for quote_

We always aim to become an excellent supplier of ASTM D92 Automatic Cleveland Open Cup Flash Point and Fire Point Apparatus, follow the business philosophy of 'integrity, cooperation, and win-win', and actively provide customers with high-quality products services. Looking forward to the future, our employees will be grateful and pursue outstanding performance to give back to the society and serve customers. Our company has been taking 'integrity, quality, service' as our business philosophy. All departments supervise and coordinate with each other, implement the concept to every detail and provide more thoughtful service for the demand groups.

Hot Tags: HZKS-3 Automatic Cleveland Open Cup Flash Point Apparatus, China, suppliers, manufacturers, price, for sale, Automatic Cleveland Open Cup Flash Point Tester, flashpoint tester cleveland, Open Cup Flash Point Analyzer, opencup flash point analyser, Cleveland Open-Cup (COC) measure, HZKS-3, hzks3, open cup flash fire point tester, manual flash point tester, Digital Insulation Resistance Tester Price, Sf6 Gas Leakage Tester, Lightning Arrester Test set, micro ohm meter, high power transformer oil treatment machine

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message