
ASTM D664 Automatic Oil Acid Value Tester Transformer Oil Acidity Analysis
Product Introduction
We uphold the attitude of integrity, sincerity and responsibility, optimize the product structure, and provide agents and consumers with more high-quality, reliable and cost-effective ASTM d86 Distillation Test Equipment, impulse voltage test system, capacitance and tan delta test set. We constantly strengthen the innovation orientation of talent mechanism to make the enterprise and staff become a community of interests, a community of career and a community of fate. We aim at 100% product qualification rate, 100% contract fulfillment rate, and 100% service satisfaction rate. Adhering to the concept of 'User's success is our achievement', we sincerely welcome friends from all walks of life to come and guide us.
HZCS-3 Transformer Oil Total Acid Number Tester
Summary
HZCS-3 Transformer Oil Acid Tester is a fully automated measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The instrument will automatically search the samples, inject the extraction, make a blank titration, do an experiment, clean off, display printing results and other operations as long as the operator put the sample cups in the sample cup holes and inject the extraction in the cup. Once started, 1 to 3 samples can be measured, which is convenient and high efficiency.
Tech Index
|
Test range |
0.002~1mg KOH/g |
|
Test error |
≤±0.005mg KOH/g |
|
Repeatability |
≤0.005mg KOH/g |
|
Ambient temperature |
10℃~45℃ |
Operation Notice
1. The peristaltic pump hose is easy to wear. Please check whether the hose is damaged or adhesion carefully to reduce the impact on the instrument.If there is any abnormal, replace the hose. After the instrument finished, please release the squeeze arm of the peristaltic pump to prevent the peristaltic pump hose from being damaged by the arm.
2. It is recommended to re-calibrate with standard acid if the instrument is not used for more than three months.
3. When preparing the extract, the container must be dry and cannot have water. The extract is sealed and stored.
4. When the test is continuous, it is allowed that the cup cannot be cleaned. If not, the cup must be cleaned and the sample cups should be completely dry before use.
5. After the test must be cleaned off.
Packing List
|
No. |
Item |
Qty |
|
1 |
Main engine |
1 |
|
2 |
Neutralization liquid medicine |
2 |
|
3 |
Extracted liquid medicine |
2 |
|
4 |
Gas washing bottle medicine |
1 |
|
5 |
Indicator |
1 |
|
6 |
Standard acid |
1 |
|
7 |
Microsyringe |
1 |
|
8 |
Sample cup |
4 |
|
9 |
Stirrer |
5 |
|
10 |
Glass bottle |
3 |
|
11 |
Glass bottle cap |
3 |
|
12 |
Tubing for Peristaltic Pumps |
1 |
|
13 |
Print paper |
2 |
|
14 |
Power line |
1 |
As ASTM D664 Automatic Oil Acid Value Tester Transformer Oil Acidity Analysis manufacturer, we continue to introduce different series of high-quality products, and develop together with the company' s new and old customers and colleagues from all walks of life to create brilliant. Besides, customized orders are also available. We have formed a spatial pattern of multi-point layout, multi-force and multi-linkage, and have maintained a high growth trend.
Hot Tags: HZCS-3 Transformer Oil Total Acid Number Tester, China, suppliers, manufacturers, price, for sale, petroleum products acid number tester, oil acid value test machine, transformer oil testing photos, Automatic Insulation Oil Acid Tester, total acid number oil analyzer, hzcs-3 total acid number oil analysis test kit, hzcs3, lubricants total acid number tester, automatic oleic acid tester, 6000a measure current power quality analyzer, lubricating oil abrasion tester, pour point test equipment, 50kv insulation resistance tester, crude oil sediment content test equipment, engine oil friction test machine
[[ProKeywords]]SPEC DATA
Send Inquiry
