We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for CT PT Analyzer, SF6 Gas Purity Analyzer, transformer oil purification equipment. How to make full use of the existing patent technology to do a good job of technological innovation is a practical problem that every enterprise must face. We are striving to move forward with a new posture of being based on ourselves, integrating into the whole country and going to the world.
HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester
Brief Introduction
HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester is usually used to measure the dielectric loss factor and DC resistivity of insulating oil and other insulating liquids. This instrument is characterized by an integrated structure, integrating the main components such as test unit, temperature controller, temperature sensor, standard capacitor, high resistance meter and DC high voltage source.
Features
The excellent quality of our Insulating Oil Dielectric Loss and Resistivity Tester makes us win the trust of customers. The instrument adopts full digital technology and intelligent automatic measurement, equipped with a large color screen (800 * 480) LCD display, which can display the test data in real time, making the operation simple and convenient. Its test results of each step can be automatically stored and printed out, so that operators without professional training will be able to use this insulating oil dielectric loss and resistivity tester skillfully.
Tech Data
Measuring range | |
Electric capacity | 5pF~200pF |
Relative Permittivity | 1.000~30.000 |
Dielectric loss factor | 0.00001~100 |
DC Resistivity | 2.5MΩm~20TΩm |
Measuring accuracy | |
Electric capacity | ± (1% of measured value+0.5pF) |
Relative Permittivity | ±1% of measured value |
Dielectric dissipation factor | ± (1% of measured value+0.0001) |
DC Resistivity | ±10% of measured value |
Resolution | |
Electric capacity | 0.01pF |
Relative Permittivity | 0.001 |
Dielectric dissipation factor | 0.00001 |
Measured temperature range | 0~120℃ |
Temperature measurement error | ±0.5℃ |
Test Voltage AC(RMS) | 500~2000V Continuously adjustable, frequency 50Hz |
Test Voltage DC | 300~500V Continuously adjustable |
Power consumption | 100W |
External dimensions | 500×360×420 |
Total weight | 22Kg |
Use Condition
Ambient | Temperature:0℃~40℃ |
Relative | Humidity(RH):<75% |

HZJD-2Z Automatic Insulating Oil Dielectric Loss And Resistivity Tester









Our Alibaba China Supply Transformer Oil Relative Permittivity Dielectric Loss Tester occupy a large market space. Our products are based at home and abroad and have been sold in many countries in the world. We believe that unity can enhance cohesion, can exert gravitational effect, and at the same time can effectively encourage everyone to make their own efforts for the development of the company. Our products under the guidance of full-time engineers, strict control of technology, production, to ensure the quality of products.
Hot Tags: HZJD-2Z Insulating Oil Dielectric Loss and Resistivity Tester, China, suppliers, manufacturers, price, for sale, oil dielectric loss measuring instrument, oil dielectric loss and volume resistivity tester, Transformer oil dielectric loss testing equipment, Insulation Oil Dielectric Loss Angle Tester, oil dielectric loss factor measurement equipment, Oil Dissipation factor test, HZJD-2Z, electric insulation oil dielectric loss test machine, electric insulating oil dielectric loss analyzer, hzjd2z, insulation oil dielectric loss and electrical resistivity tester, Circuit Breaker Analysis kit, Sweep Frequency Response Analyzer, power cable identifier, SF6 Gas Purity Test Set, TDR Cable Fault Locator, variable frequency ct pt tester