+86-312-6775656
2020 New LCD Multiple Pating Systems Battery Tester Analyze Voltage, CCA Value, Resistance

2020 New LCD Multiple Pating Systems Battery Tester Analyze Voltage, CCA Value, Resistance

Battery Load Bank is a special instrument for the test of NiCD and Lead-acid storage battery string of the whole string voltage of 24V, 48V, 110V, 220V, in communication room
Send Inquiry
Product Details of 2020 New LCD Multiple Pating Systems Battery Tester Analyze Voltage, CCA Value, Resistance

Product Introduction

We focus on the development positioning of providing customers with a full range of quality zinc oxide arrester test, Single Phase Relay Tester, ct pt characteristics tester and services, and strive to make the company a world class enterprise with global competitiveness. We, with fantastic passion and faithfulness, are willing to offer you with best services and striding forward with you to make a bright foreseeable future. We insist on competing with strength, seeking returns with dedication, and speaking with performance in order to continue to create value for society.

HZFD-200 Battery Load Bank Discharge Tester

CE Certificate

battery discharge tester

HZFD-200_Battery Discharge Tester

HZFD-200_Battery Discharge Tester

HZFD-200_Battery Discharge Tester

HZFD-200_Battery Discharge Tester

HZFD-200_03

Introduction

The DC load bank is a specialized instrument designed for testing Ni-Cd and lead-acid storage battery strings in communication facilities. It supports whole-string voltage testing for 24 V, 48 V, 110 V, and 220 V battery banks, as well as individual cell voltage testing for 1.2 V, 2 V, 6 V, and 12 V cells.

Utilizing advanced testing technology, the instrument incorporates breakthroughs in new techniques, components, materials, and processes. It is designed in accordance with national testing and maintenance regulations, making it a specialized tool for stationary battery performance evaluation.

With high discharge power, compact size, light weight, and comprehensive PC-based data management software, the battery load bank significantly reduces the workload associated with daily testing and maintenance of stationary batteries.

Battery Discharge Tester

Applicable battery

Lead-acid battery

Output voltage

110V

220V

Output current

0-180A

0-90A

Operating mode

Used independently or with a constant-current module

Protection performance

Input terminal overvoltage protection, prompts on the LCD;
Reverse polarity protection, buzzer alarm;
Overcurrent protection, prompts on the LCD;
85℃ overheat protection, prompts on the LCD, buzzer alarm.

Single battery voltage acquisition

The 433RF wireless module supports a communication distance longer than 100 m and monitoring for single battery voltages of 2V, 4V, 6V and 12V. If the total voltage is not beyond the set value, each battery pack will have an unlimited single battery quantity and can monitor one to sixteen RF wireless monitoring modules at the same time. One RF wireless monitoring module can monitor 12 single batteries at the same time.

Control accuracy

Discharge current: ≤±1%; battery pack's terminal voltage: ≤ ±0.1%; single battery voltage: ≤±0.05%

Communication with the host PC

RS485 interface

Data storage capacity

2Gbit FLASH

Operating conditions

Cooling

Forced air cooling

Temperature

Operating temperature: -5~50℃; storage temperature: -40~70℃

Humidity

Relative humidity: 0~90% (40±2℃)

altitude

Rated altitude: 4,000 m

Noise

﹤60dB

Operating power supply

Voltage

Single-phase three-wire system: 220V AC (–20%~+30%); frequency: 45~65Hz;

Withstand voltage test

Input--casing: 2200Vdc 1min
Input--output: 2200Vdc 1min
Output--casing: 700Vdc 1min

Wiring

AC output

Male socket in line with the applicable national standard, applicable to 1~1.5mm2 cable

DC output

25mm2 cable quick plug (red: positive; black: negative)

After-sales Service

Within one year from the date of purchase, any quality issues caused by the company will be covered by free maintenance. Lifelong maintenance and technical support are also provided.

If any abnormality or malfunction is detected during use, please contact the company promptly. We will arrange the most convenient solution and provide the fastest on-site service to address your needs.

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428

image012

image014

Request for quote_

We absorb the management experience of large enterprises in our company management, implement total quality management, and establish a scientific quality assurance system to ensure the product quality of processed 2020 New LCD Multiple Pating Systems Battery Tester Analyze Voltage, CCA Value, Resistance. We will bear in mind our mission, never forget our original intention, and make new and greater contributions to strengthen and expand our business and achieve social progress! We need to strengthen the construction of corporate system culture while focusing on the construction of value concept system.

Hot Tags: HZFD-200 DC Load Bank Battery Discharge Tester, China, suppliers, manufacturers, price, for sale, 48vdc load bank, Battery Discharge Machibe 48V 200A, battery load bank testing, battery discharger & capacity tester, Battery Discharge Test Kit, dc loadbank, hzfd-200, battery discharge tester 12v 24v, high current battery load tester, detection battery discharger, battery load unit 200vdc, battery tester load 300a, insulating oil recycling machine, variable inductance resonant test system, sf6 gas dew point meter, 3 Phase Primary Current Injection Test Set, vlf insulation meter, single phase transformer dc winding resistance tester

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message