+86-312-6775656
HZ211S-10 10kV Turn To Turn Surge Withstand Tester

HZ211S-10 10kV Turn To Turn Surge Withstand Tester

HZ211S-10 10kV Turn To Turn Surge Withstand Tester HZ211S-10/HZ212S-10 series Turn to Turn Surge Impulse Tester, which is manufactured by our company, adopts micro computer technology to quantize various parameters of waveform, and then use the intuitive waveform for display and judgment. Its...
Send Inquiry
Product Details ofHZ211S-10 10kV Turn To Turn Surge Withstand Tester

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of hz211s-10 10kv turn to turn surge withstand tester in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

HZ211S-10 10kV Turn To Turn Surge Withstand Voltage Tester

 

HZ211S-10/HZ212S-10 series Turn to Turn Surge Impulse Tester, which is manufactured by our company, adopts micro computer technology to quantize various parameters of waveform, and then use the intuitive waveform for display and judgment. Its operation is simple, its judgment is accurate, and its degree of automation is high. The instrument is small in size, and light in weight, which is easy to carry.

 

Main technical indexes

Model

HZ211S-03

HZ212S-03

HZ211S-05

HZ212S-10

HZ211S-10

Number of channels

1 channel

3 channel

1 channel

3 channel

1 channel

Range of pulse voltage

300V-3KV

500V~5KV

1KV-10KV

Accuracy of pulse voltage

±5%±15V

±5%±25V

±5%±50V

Step of pulse voltage

50V

100V

200V

Measurement speed

Approx. 5 times/s

High-voltage power supply control

Switching power supply is controlled by MCU

Numbers of impulses

Single EXT (1-29 times); continuous INT

Trigger mode

Manual, Foot control, PC

Detection and judgment mode

Area; differential area; corona discharge quantity; phase

Sound mode

"Up to standard" sound; "Not up to standard" sound; mute

Storage capacity of waveform

100 waveforms and their parameters

Waveform resolution

A/D: 8 bit; sampling speed: 25nS (40MHz); point number of waveform: 250

LCD

Resolution: 320 x 240; 5.1 inches; white letters on a blue background

Power

40W

50W

Power input

220VAC±10% 50Hz±5%

Dimension

400(W)×132(H)×430(D)

Weight

Approx. 10Kg

Environment condition

Operating temperature:10℃-30℃; Operating humidity: 20%-80% RH

Storage temperature: 5℃-40℃; storage humidity: 5%-90%RH

Special functions and parameters

Customized according to user requirements

 

Matters Needing Attention

Matters needing attention for safe use

In order to ensure the safe use of this instrument, please be sure to comply with the followings. If no attention is paid, the contact will cause electric shock, which may lead to death or serious injury.

Matters needing attention for use

The instrument shall be grounded well. Please ground the safety ground terminal on the rear panel of this instrument reliably.

Please do not touch the inside of this instrument with hands. As there is high–voltage power inside this instrument, beware of HV electric shock.

Under the state of "Test", and when the indicator light of "Stop" is not ON, do not contact the test terminal and/or tested coil, and beware of HV electric shock.

The test winding must be replaced when the indicator light of "Stop" is ON; after that, the test can be started by pressing "Start" key (or sending out "START" signal by external device).

When exceeding the limit voltage of tested object, it is very dangerous to carry out a test.

The instrument shall be used in the environment of 20℃-30℃, where good ventilation shall be ensured around the instrument.

As the instrument uses high–voltage power, please do not operate it in dusty places of high humidity.

When its power is cut off for cleaning, please use some water or a soft cloth dipped with a small amount of neutral detergent to wipe the instrument.

Please use a 3-hole socket with good grounding performance to supply the power.

 

Matters needing attention for start-up of instrument

Connect HV test terminal to a test fixture reliably, and connect the power supply to power socket, then turn on the power switch; at this time, the instrument LCD screen is lit, and accompanied with an alarm sound, meanwhile the instrument enters the initialization interface; two seconds later, the instrument will automatically enter the state to "Ready- to- test".

Matters needing attention for use of sound mode

When the instrument is in operation, the sound mode shall be one of "Up to standard" sound, "Not up to stan

dard" sound and mute.

Under the mode of single EXT for number of Impulses (0-29) :

"Up to standard" sound: Send out a sound only when the test results are up to standard. When reaching the number of times, and stopping the test, if the test results are up to standard, send out a long sound, which needs to be turned off by using "Stop" key.

"Not up to standard" sound: Only when the test results are Not up to standard, stop the test, and send out a long sound, which needs to be turned off by using "Stop" key.

Mute: When the test results are either up to standard or not up to standard, do not send out any sound.

Under the mode of continuous INT for number of Impulses (>29 times) :

"Up to standard" sound: Only when the test results are up to standard, send out a single short sound.

"Not up to standard" sound: Only when the test results are Not up to standard, send out a single short sound.

Mute:When the test results are either up to standard or not up to standard, do not send out any sound.

 

lQDPKcrtGtmqmW_NAazNAyCw_iF2foFjEn0JNdw6T7ADAg_800_428