+86-312-6775656

HZQS37G High Voltage Schering Bridge

May 22, 2024

HZQS37G High Voltage Schering Bridge

 

1. Overview

The HZ QS37G High Voltage Schering Bridge is mainly used to measure the tangent value and capacitance of the dielectric loss angle of high-voltage industrial insulation materials. It adopts the classic circuit of Xilin Electric Bridge. It can mainly measure the dielectric loss (tg) and capacitance (Cx) of capacitors, transformers, various electrical oils, and various solid insulation materials under high voltage from power frequency to 1000Hz. The measurement circuit adopts the "positive connection method" to measure the insulation of the test object to ground. The bridge is composed of a bridge body, a high-frequency zero indicator, a standard capacitor, etc. This bridge is particularly suitable for measuring the dielectric loss (tg) and dielectric constant of various insulation oils and solid insulation materials( ε).

2. Technical indicators

2.1 Measurement Range and Error

The ambient temperature of this bridge is 20 ± 5 ℃, and the relative humidity is 30% -80%. It should meet the following conditions:

The technical instructions in the following table are required.

When Cn=100pF R4=3183.2() (i.e. 10K/π)

QQ20240522161639

Measurement project   measurement range   measurement error

Capacitance            Cx 40pF --20000pF ± 0.5%    Cx ± 2pF

Dielectric loss             tg 0-1 ± 1.5%                  tgx ± 0.0001

When Cn=100pF R4=318.3() (i.e. 1K/π)

Measurement project   measurement range   measurement error

Capacitance Cx            4pF --2000pF ± 0.5%     Cx ± 3pF

Dielectric loss              tg 0-0.1 ± 1.5%               tgx ± 0.0001

2.2 Accuracy of capacitance and dielectric loss display:

Capacitance: ± 0.5%

Dielectric loss: ± 1.5% tgx ± 1 × 10-4