+86-312-6775656
VLF Hipot Tester With Integrated Tan Delta And Partial Discharge

VLF Hipot Tester With Integrated Tan Delta And Partial Discharge

HZVLF90TS VLF Hipot Tester with Integrated Tan Delta and Partial Discharge Product Features This product utilizes digital frequency conversion technology and microcontroller-based control, achieving fully automated voltage step-up, step-down, measurement, and protection. Thanks to its fully electronic...
Product Details ofVLF Hipot Tester With Integrated Tan Delta And Partial Discharge

Huazheng Electric Manufacturing (Baoding) Co., Ltd. is one of the leading manufacturers and suppliers of vlf hipot tester with integrated tan delta and partial discharge in China. Please feel free to buy high quality equipment for sale here from our factory. Good service and reasonable price are available.

 

VLF Hipot Tester with Integrated Tan Delta and Partial Discharge

 

Product Features

This product utilizes digital frequency conversion technology and microcontroller-based control, achieving fully automated voltage step-up, step-down, measurement, and protection. Thanks to its fully electronic design, it is compact and lightweight. It features a large color touch screen that provides clear and intuitive operation and displays output waveforms. The main features are as follows:

1 For rated voltages ≤60kV, a single-unit structure (one voltage booster) is used; for voltages >60kV, a series structure (two voltage boosters in series) is adopted, significantly reducing overall weight and enhancing load capacity. Additionally, both boosters can be used independently, allowing for multiple applications. Products within 60kV also offer an integrated structure: a plastic pull-rod casing for extremely simple operation.

2 Current and voltage data are directly sampled from the high-voltage side. Due to the closed-loop negative feedback control circuit, the output is free from capacitive rise effects.

3 Intelligent comprehensive protection: No need to set current or voltage protection values. The device automatically calculates overvoltage and overcurrent protection values based on the test sample's capacitance and the test voltage. It can trigger protective shutdown in cases of overvoltage, overcurrent, low-resistance faults in the test sample, or flashover.

4 Equipped with a 150kV high-voltage output cable for safety and reliability.

5 The new model adds DC, dielectric loss, and partial discharge testing functions. During the withstand voltage test, it can simultaneously measure the dielectric loss, capacitance, insulation resistance, and partial discharge of the test sample.

 

Rated Voltage Load Capacity Product Structure, Weight, Application Range
30kV (Peak) Automatic frequency variation: 0.1Hz-0.01Hz Controller: 4kg
Load capacity: ≤10µF Booster: 25kg
  For withstand voltage testing of cables and motors up to 10kV
40kV (Peak) Automatic frequency variation: 0.1Hz-0.01Hz Controller: 4kg
Load capacity: ≤10µF Booster: 25kg
  For withstand voltage testing of cables and motors up to 10kV
50kV (Peak) Automatic frequency variation: 0.1Hz-0.01Hz Controller: 4kg
Load capacity: ≤6µF Booster: 25kg
  For withstand voltage testing of cables and motors up to 15kV
60kV (Peak) Automatic frequency variation: 0.1Hz-0.01Hz Controller: 4kg
Load capacity: ≤5µF Booster: 25kg
  For withstand voltage testing of cables and motors up to 25kV
80kV (Peak) Automatic frequency variation: 0.1Hz-0.01Hz Controller: 4kg
Load capacity: ≤6µF (within 50kV), ≤4µF (above 50kV) Primary booster (40kV): 25kg
  Secondary booster (40kV): 45kg
  For withstand voltage testing of cables and motors up to 35kV
90kV (Peak) Automatic frequency variation: 0.1Hz-0.01Hz Controller: 4kg
Load capacity: ≤6µF (within 50kV), ≤4µF (above 50kV) Primary booster (40kV): 25kg
  Secondary booster (40kV): 45kg
  For withstand voltage testing of cables and motors up to 35kV

 

General Technical Specifications of the Ultra-Low Frequency High-Voltage Power Supply

1 Rated output voltage: 30kV-80kV (see Table 1 for different specifications).
2 Output frequency: Automatic frequency variation range: 0.1Hz-0.01Hz.
3 Load capacity: See Table 1.
4 AC voltage resolution: 0.1kV.
5 Voltage accuracy: 3%.
6 AC current resolution: 0.1mA.
7 AC current accuracy: 3%.
8 Positive and negative peak voltage error: ≤3%.
9 Voltage waveform distortion: ≤3%.
10 Operating conditions: Indoor and outdoor; temperature: -10°C to +40°C; humidity: ≤85% RH.
12 Grounding detection function: Operation is prohibited if grounding is not detected.

 